SDS / Technical Data Patented cooling system 4 top inlets Silicone rubber check valve for quiet operation Thermal overload protection Dual float switch controls for added safety Independent safety float switch (except item 15660) UL/cUL Listed 60 Hz 6' power cord. Condensate Pump for Beckett Part# CB201UL. Hobart slicers are the preferred choice for many restaurants and other foodservice centers to make food preparation as easy as possible.
- Beckett Cb201ul Manual
- Beckett Condensate Pump Cb201ul Manual Instructions
- Beckett Condensate Pump Cb201ul Manual Free
Description
Small Condensate Model # CB12 Series
Beckett’s most recent addition to its condensate family offers the best overall performance available in a small pump. The CB12 size allows easy accessible installation, minimum service and consistent reliability for all your smaller condensate removal needs. Usable in both the standard HVAC and mini-split markets, this compact pump is uniquely designed to be extremely quiet and can either be placed inside the air conditioner, within a ceiling compartment or wall mounted unit. Dual mounting slots on the tank allow for multi-directional placement applications. Pump is rated for 115V, 60Hz. UL/CUL listed. Average sound level less than 37 dba.
H | W | L | Outlet | Volts | Amps | Watts | H.P.* | GPH @ 60Hz/Rated Voltage | Safety Switch | Check Valve | 6 foot cord w/plug | Tubing | Hi-Eff. Gas Furn. | Shut Off(ft) | Weight Lbs. Ea. | ||
1′ | 5′ | 10′ | |||||||||||||||
5 1/8″ | 3 1/8″ | 7 1/2″ | 3/8″ O.D. | 115 | .5 | 29 | 1/100 | 57 | 36 | 12 | Y | Y | Y | N | Y | 12.5′ | 3.5 |
Condensate pumps work to pump the water that is created in a heating or boiling system. Cara download software di torrent. But if your condensate pump isn’t functioning as it should, it might need to be cleaned, repaired, or potentially replaced.
If the condensate pump isn’t working correctly, it’s dangerous to run your air conditioning system because it can cause water damage and other costly repairs in the long run. Knowing how to troubleshoot a broken condensate pump is essential to ensure your system gets the repairs it needs before a bigger issue occurs. Here’s how you can troubleshoot your condensate pump in five simple steps.
Step 1. Turn the Power off to Your AC and Condensate Pump
Beckett Cb201ul Manual
If you suspect your condensate pump might be broken, turn the power off to your AC and the condensate pump. Make sure you turn off the power to the high voltage and low voltage wires from the pump.
Step 2. Check the Float
![Beckett Condensate Pump Cb201ul Manual Beckett Condensate Pump Cb201ul Manual](https://i.ebayimg.com/images/g/ZpkAAOSwGzdfJo1M/s-l640.png)
All condensate pumps have a float, which is located at the top of the pump. This small piece can sometimes become stuck and cause the pump to shut off. If the float is stuck, simply tap on it until it can move freely again. If you notice the float is cracked or damaged, you will need to replace it.
Step 3. Clean the Pump
After completing steps one and two, clean the pump thoroughly. Remove the outer housing of the pump and dump the water from both the pump and the tank. Use warm soapy water and a clean washcloth to clean the entire unit, including the float.
Step 4. If It’s Still Not Working, Remove the Pump
If the pump is still not working after cleaning, use a pair of wire cutters to cut the lines that are connected to the pump. Be sure to leave part of the wire so you will have some to work with when replacing the pump.
Step 5. Remove the Old Pump and Install the New One
Utorrent free download for windows 10 movies. Carefully remove the old pump from its position and replace it with a new pump. Reconnect the electrical wiring and insert the new plumbing lines. Once you have installed the new pump, turn it on and pour water into the pump to test. If the pump stops running once the water is poured, continue adding water until it works correctly.
Beckett Condensate Pump Cb201ul Manual Instructions
Residential AC Repair In Orlando
Beckett Condensate Pump Cb201ul Manual Free
Sometimes home projects are better left to the professionals. If your condensate pump has stopped working and you’re not sure how to fix it, Energy Air can help. We provide a variety of AC repair services to homeowners in the Orlando area and beyond and will provide a quick, quality repair. Contact us today to learn how we can help, or conveniently schedule a service online.